MKII Addressable Detectors

Standard Detectors

MKII Addressable Smoke Detectors

The Fyreye MKII optical smoke detector (MKII-AOP) uses a pulsing IR LED & photodiode to detect IR scatter caused by smoke entering the chamber.

The detector is particularly suitable for detecting optically dense smoke, involving materials such as soft furnishings, PVC, plastic, foam and all similar materials which produce small visible particles (0.5 to 10μm).

Model Number Description Datasheets & Manuals
MKII-AOP MKII Addressable Optical Smoke Detector

Datasheet

Installation Guide

MKII-AOP/B Black MKII Addressable Optical Smoke Detector
MKII-AOH MKII Addressable Combined Optical Smoke & Heat (A1R) Detector
MKII-AOH/B Black MKII Addressable Combined Optical Smoke & Heat (A1R) Detector

Fyreye MKII Addressable Heat Detectors

The Fyreye MKII Rate of Rise heat detector (MKII-AHR) uses a thermistor arrangement to sense a quick rise in temperature and also a final threshold temperature of 57°C. The Fyreye fixed heat detector (MKII-AHF) has a single thermistor arrangement that gives an alarm at a temperature of 57°C, where the MKII-AHF/ CS90 gives an alarm above 86°C.

Model Number Description Datasheets & Manuals
MKII-AHF MKII Addressable Fixed Heat Only A2S Detector

Datasheet

Installation Guide

MKII-AHF/B Black MKII Addressable Fixed Heat Only A2S Detector
MKII-AHF/CS90 MKII Addressable Fixed Heat Only CS Detector
MKII-AHF/CS90/B Black MKII Addressable Fixed Heat Only CS Detector
MKII-AHR MKII Addressable Rate of Rise & Fixed Heat Detector A1R Detector
MKII-AHR/B Black MKII Addressable Rate of Rise & Fixed Heat Detector A1R Detector

Detectors With Built In Isolators

MKII Addressable Smoke Detectors with Built In Isolators

The Fyreye MKII optical smoke detector with built in isolator (MKII-AOPI) uses a pulsing IR LED & photodiode to detect IR scatter caused by smoke entering the chamber.

The detector is particularly suitable for detecting optically dense smoke, involving materials such as soft furnishings, PVC, plastic, foam and all similar materials which produce small visible particles (0.5 to 10μm).

Model Number Description Datasheets & Manuals
MKII-AOPI MKII Addressable Optical Smoke Detector With Built-In Isolator

Datasheet

MKII-AOPI/B Black MKII Addressable Optical Smoke Detector With Built-In Isolator
MKII-AOHI MKII Addressable Combined Optical Smoke & Heat (A1R) Detector With Built-In Isolator
MKII-AOHI/B Black MKII Addressable Combined Optical Smoke & Heat (A1R) Detector With Built-In Isolator

Fyreye MKII Addressable Heat Detectors with Built In Isolators

The Fyreye MKII Rate of Rise heat detector with built in isolator (MKII-AHRI) uses a thermistor arrangement to sense a quick rise in temperature and also a final threshold temperature of 57°C.

The Fyreye fixed heat detector with built in isolator (MKII- AHFI) has a single thermistor arrangement that gives an alarm at a temperature of 57°C, where the MKII-AHFI/ CS90 gives an alarm above 86°C.

Model Number Description Datasheets & Manuals
MKII-AHFI MKII Addressable Fixed Heat Only A2S Detector With Built-In Isolator

Datasheet

MKII-AHFI/B Black MKII Addressable Fixed Heat Only A2S Detector With Built-In Isolator
MKII-AHFI/ CS90 MKII Addressable Fixed Heat Only CS Detector With Built-In Isolator
MKII-AHFI/ CS90/B Black MKII Addressable Fixed Heat Only CS Detector With Built-In Isolator
MKII-AHRI MKII Addressable Rate of Rise & Fixed Heat Detector A1R Detector With Built-In Isolator
MKII-AHRI/B Black MKII Addressable Rate of Rise & Fixed Heat Detector A1R Detector With Built-In Isolator

Addressable Remote LED Indicators

There are two models for the remote LED indicator, a wall type MKII-ARL/W and ceiling mounted type (requires a base) MKII-ARL/C.

Each unit is equipped with 8 LEDs and mimics the detector LED in alarm condition.

Model Number Description Datasheets & Manuals
MKII-ARL/C Ceiling Mounted Addressable Remote LED Indicator

Datasheet

MKII-ARL/W Wall Mounted Addressable Remote LED Indicator

Assessed to ISO 9001:2015 - Certificate Number 330 DBI BSI Intertek VdS