Fyreye MKII Addressable Input Module With Isolator
The ZAI-MI is used to monitor and raise alarm from any ancillary equipment such as sprinkler flow switch, aspiration detectors, secondary fire control panel, beam detectors, external power supplies etc.
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZAI-MI | Fyreye MKII Addressable Input Module with S/C Isolator (Loop Powered) |
Fyreye MKII Addressable Input/Output Module With Isolator
The ZAIO-MI is both an input and output module in a modern enclosure (2 gang box size) with well protected electronic circuit board to minimise any damages during installation.
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZAIO-MI | Fyreye MKII Addressable Input/Output Module with S/C Isolator (Loop Powered) |
Fyreye MKII Addressable Sounder Control Module With Isolator
The ZASC-MI can be used to supply a monitored 24Vdc to operate external relays and as a conventional sounder circuit to run bells or beacon flashers where the current consumption prohibits the use of addressable loop powered devices. The unit also includes input connections to monitor the external power supply status and report the findings to the addressable control panel.
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZASC-MI | Fyreye MKII Addressable Sounder Circuit Controller with S/C Isolator (Needs External Power Supply) |
Fyreye MKII Addressable Zone Monitor Module With Isolator
The ZAZM-MI is a conventional zone that can be used for conventional devices and/or for special detectors that are not available in addressable form such as UV detectors, Aspiration detectors etc.
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZAZM-MI | Fyreye MKII Addressable Zone Monitoring Unit with S/C Isolator (Loop Powered) |
Zeta Addressable Input/Output Module with Isolator - 230V Switching
This interface can be used to switch 8A at 230V AC. It can only be addressed with it’s DIP switch
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZAIO/230 | Mains switching I/O unit - Fyreye MKII Protocol, 8A @ 230V AC |
Special Mini Modules
Model Number | Description | Datasheets & Manuals |
---|---|---|
SMM/S | Special Mini Modules (Yellow) - Alarm Devices This module allows a conventional sounder or flasher to be connected to an addressable loop (Max current 12mA. 24 per loop). |
|
SMM/B | Special Mini Modules (White) - Beam Detector This module allows the Zeta Beam - auto aligning beam detector to be connected to an addressable loop (Max 16 per loop). |
|
SMM/C | Special Mini Modules (Red) - Call Point This module provides a call point alarm input, that can be connected to a keyswitch to provide restricted alarm activation. It can also be used to connect to 3rd party conventional call points if required. |